Sign In | Join Free | My benadorassociates.com
China Melan Measurement & Control Instruments (Shanghai) Co.,Ltd. logo
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.
Site Member

6 Years

Home > Electromagnetic Flow Meter >

IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
Contact Now

IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter

  • 1
  • 2

Model Number : MLF

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 500pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton or Wooden Box

Product Name : Electromagnetic Flow Meter

Pipeline Diameter : DN15-DN2000

Accuracy : 0.5% or 0.2%

Flange : GB/ANSI/JIS/BS/Others

Pressure Rate : 0.6MPa-4.0Mpa

IP Class : IP65/IP67/IP68

Contact Now

Magnetic Flow Meter for Industrial Process Measurement with High Performance​

1. Introduction

MLF electromagnetic Flowmeter works according to Faraday's law of electromagnetic induction and is composed of sensors and converters. Used to measure the electrical conductivity of liquids or solids. In general, its electrical conductivity should be greater than 5 μ S / cm (the electrical conductivity of tap water and raw water is about 100 ~ 500 μS / cm), can also be used to measure various media such as acid, alkali, salt water, pulp or pulp. But these media cannot contain large amounts of magnetic materials and bubbles.

MLF electromagnetic Flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, waterworks and other industries.

2. Features

MLF electromagnetic Flowmeter is explosion-proof design.

function of low conductivity measurement.

There are 9 languages(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

Have self-regulation function and self-examination.

different outputs are optional: hart, RS485 Profibus ,4-20 mA, frequency, pulse.

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

4. Selection of Electrode Materials

Electrode Material Main Performance
316L Good corrosion resistance of nitric acid, sulfuric acid, acetic acid, alkaline liquid at room temperature < 5%, sulfite, seawater, acetic acid and other corrosion under certain pressure, can be widely used in petrochemical urea, vinylon and so on.
Hb Good resistance to all concentrations below the boiling point of hydrochloric acid, but also resistant to non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.
Hc Resistant to the corrosion of oxidizing acid, such as nitric acid and mixed acid. The mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3+, Q3+, and other oxidants, such as the mixture of hypochlorite solution and seawater at higher than normal temperature.
Ti Resistant to corrosion of seawater, various chlorides, hyalphates, oxidizing acids (including smoke nitric acid), organic acids or alkalis, but not pure reduced acids (e.g. sulphuric acid, hydrochloric acid). However, if the acid contains oxidants (e.g. nitric acid, Fe3, Q3), corrosion resistance is reduced.
Ta Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-Ir Have good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten Carbide For pulp and sewage, good resistance to solid particle interference.

5. Dimensional Sketches

a. Dimension of Converter

IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter

Divided Type

IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter

Integrated Type

IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter

Battery Powered Type

b. Dimension of Sensor

IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

7. Instrument Detection & Maintenance

The electromagnetic Flowmeter has the function of self-diagnosis. In addition to power supply and hardware circuit failures, the system also gives an alarm to other faults in general use. These messages are prompted in the lower right corner of the screen.

1 Maintenance and repair.

A) the sensor installation site should meet the requirements of Section 4, please keep the shell clean and tidy.

B) the transmitter should be placed in a clean, ventilated and dry place.

C) it needs to be checked every two years, and for high-precision users, the instrument needs to be submitted for review.

2 Transportation and storage.

A) the equipment must be packed before transportation and handled carefully during loading and unloading.

B) the storage place must be dry and ventilated to avoid the erosion of corrosive gases and the ambient temperature should not be too low or too high.

C) the storage time should not exceed three years.

3. Out-of-the-box inspection.

A) the package cannot be opened with a heavy hammer, be careful not to damage the instrument.

B) carefully check the contents according to the packing list.


Product Tags:

DN15 Magnetic Flow Meter

      

4.0Mpa Magnetic Flow Meter

      

IP68 Electromagnetic Flow Meter

      
Quality IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter for sale

IP68 10m/S Velocity 4.0Mpa DN15 Magnetic Flow Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)